首页 SOLIDEX® SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based)

SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based)

🏷 GM-Tg-hg-T23212-iso-nanoIMB
DirectColumn-basedNon-releasable
Efficiently isolate Human CD14+ Cells (Monocytes) with SOLIDEX®-ISOEx Nanobeads. Utilizing a robust Positive Selection strategy, this kit specifically targets CD14 antigens to maximize recovery from PBMC or Leukopaks. The Column-based format combined with advanced Magnetic Beads allows for rigorous washing, ensuring High Purity and minimal background contamination. The biodegradable nanobeads are gentle on cells, making them ideal for downstream differentiation into Dendritic Cells (Mo-DCs) or Macrophages without artificial activation.
SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based) is a Direct CD14+ Cell Isolation Nanobeads (Column-based, Non-releasable)
📄 MSDS

订购信息

产品货号 产品名称 规格 价格 (USD)
GM-Tg-hg-T23212-iso-nanoIMB-10T SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based) 10 Tests $112
GM-Tg-hg-T23212-iso-nanoIMB-50T SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based) 50 Tests $336
GM-Tg-hg-T23212-iso-nanoIMB-100T SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based) 100 Tests $591
GM-Tg-hg-T23212-iso-nanoIMB-750T SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based) 750 Tests
SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based)

产品规格

  • 目标细胞群 CD14+ Cell
  • 标记类型 Direct
  • 磁珠类型 Non-releasable
  • 分选方式 Column-based
  • 分离方法 Positive CD14+ Cell Selection
  • 储存条件 2℃ - 8℃ 保存

产品详情

产品货号 GM-Tg-hg-T23212-iso-nanoIMB
产品名称 SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based)
英文名称 SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based)
产品详情 SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based) is a Direct CD14+ Cell Isolation Nanobeads (Column-based, Non-releasable)
应用详情 SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based) is used for Positive CD14+ Cell Selection, with the Key Features, such as Fast isolation; high purity; ideal for automated workflows
标记类型 Direct
磁珠类型 Non-releasable
分选方式 Column-based
关键特性 Fast isolation; high purity; ideal for automated workflows
目标细胞群 CD14+ Cell
储存条件 2℃ - 8℃ 保存

应用详情

SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based) is used for Positive CD14+ Cell Selection, with the Key Features, such as Fast isolation; high purity; ideal for automated workflows

实验方案

  1. Preparation: Prepare a single-cell suspension from Human PBMCs (fresh or frozen) or Leukopaks.
  2. Labeling: Add CD14 Microbeads directly to the cell suspension. Incubate to bind CD14+ Monocytes.
  3. Separation: Place a separation column in the magnetic field and apply the cell suspension.
  4. Washing: Magnetically labeled CD14+ cells are retained in the column; unlabeled cells (T cells, B cells, NK cells) are washed away.
  5. Elution: Remove the column from the magnet and elute the purified CD14+ Cells.

验证数据

High-purity isolation of classical monocytes from human peripheral blood mononuclear cells (PBMC) using the SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based)

Catalog No. GM-Tg-hg-T23212-iso-nanoIMB
The SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based) was used to isolate and purify CD14+ monocytes from cryopreserved PBMCs. The purity of the cell populations before and after isolation was analyzed by flow cytometry. This experiment achieved a significant increase in CD14+ monocyte purity from 15.2% to 93.7% with a recovery rate of 78.66% as verified by flow cytometry.

Figure 13. High-Purity Isolation of CD14+ Cells from Human PBMCs Using SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads (Column-based). The flow cytometry analysis of the isolated cells from PBMCs.

ISOEx Cell Isolation Kit & Nanobeads validation
Click to Zoom

背景介绍

Why Choose SOLIDEX®-ISOEx Human CD14 Isolation Nanobeads?

  • High Recovery: Positive selection efficiently captures monocytes, ensuring high yields even from donors with lower cell counts.
  • Superior Purity: The column matrix acts as a filter, allowing thorough washing of non-specific cells, resulting in higher purity compared to simple tube-based magnetic capture.
  • Differentiation Ready: The biodegradable nanobeads do not interfere with downstream differentiation into Dendritic Cells or Macrophages.
  • Minimal Activation: Optimized bead size and chemistry prevent artificial activation of monocytes during the isolation process.

常见问题

What are the sample requirements?
This kit is optimized for fresh or cryopreserved Human PBMCs. It is also highly effective with Leukapheresis products (Leukopaks). When using frozen PBMCs, ensure cells are treated with DNase to prevent clumping, which is common with thawing monocytes.
Do the magnetic beads affect cell activation or differentiation?
No. The SOLIDEX® nanobeads are biodegradable and nano-sized. They are engineered to minimize receptor cross-linking. Validated data shows they do not interfere with the differentiation of monocytes into DCs or Macrophages, nor do they induce artificial cytokine secretion.
How does the Column-based separation work?
The column contains a matrix of ferromagnetic spheres. When placed in a magnetic field, these spheres amplify the magnetic gradient, securely trapping the bead-labeled CD14+ cells. This allows for vigorous washing of contaminants before the target cells are released.
Are the separation columns reusable?
No. To maintain sterility and absolutely prevent cross-contamination between donor samples, the columns are designed for single-use only.
What is the advantage of Column-based over Column-free methods?
Column-based positive selection generally delivers higher purity. The physical column matrix allows for the washing away of non-specific cells that might get trapped in the "clumps" formed by column-free tube methods.
Is this protocol compatible with automated systems?
Yes, the SOLIDEX®-ISOEx column format is designed to be compatible with most standard automated magnetic cell separators using column technology.

需要更多产品数据或案例?